Rabu, 31 Agustus 2016

Anonim

LXC610

 The LXC610/620 is used in single machine automation, which can control the Genset starting by remote boot signal
The LXC620 added the function is based in LX610, which is automatic mains failure control module. can monitor a mains supply and automatically start.  
Working voltage DC8.0V to 35.0V (continue to supply)
Consumer power <3W (stand model: ≤2W )
Alternator Input voltage:
12V AC - 360 V AC (ph-N) 3 Phase 4wire
23V AC - 620 V AC (ph-ph) 3 Phase 3wire
12V AC - 360 V AC (ph-N)
12V AC - 360 V AC (ph-N)
Frequency 50/60HZ
Speed sensor voltage Vpp: 1.0 - 70Vpp
Speed sensor Frequency: Max 10000HZ
Starting relay output: 10Amp DC28V
Fuel relay output : 10Amp DC28V
Programmable relay output 1: 10Amp DC28V
Programmable relay output 2: 10Amp DC28V
Power switching programmable relay output 3: 10Amp 250VAC
Mains switch relay programmable relay output 4: 10Amp 250VAC
Out Size: 209mm x 146mm x 26mm
Tapping Size: 214mm x 160mm
Current transformer secondary electric 5A
Working condition: Temp. (-25~+70)°C humidity (20~90)%
Storage condition: Temp. (-25~+70)°C
Weight: 0.56kg
ItemsContents
Operating VoltageDC 8.0V to DC 35.0V, Continuous Power Supply.
Power Consumption<3W(standby:≤2W)
Alternator Input Range 
3-Phase 4-Wire 12V AC - 360 V AC (ph-N) 3 Phase 4wire
3-Phase 3-Wire 23V AC - 620 V AC (ph-ph) 3 Phase 3wire
Single-Phase 2-Wire 12V AC - 360 V AC (ph-N)
2-Phase 3-Wire12V AC - 360 V AC (ph-N)
Alternator Frequency50/60Hz
Speed sensor voltage Vpp1.0 - 70Vpp(Peak to peak)
Speed sensor Frequency10000Hz(max.)
Start Relay Output10Amp DC28V 
Fuel Relay Output 10Amp DC28V 
Programmable Relay Output 110Amp DC28V 
Programmable Relay Output 210Amp DC28V 
Gens Closed Programmable Relay Output 310Amp 250VAC Free output
Mains Closed Programmable Relay Output 410Amp 250VAC Free output
Case Dimension209mm x 146mm x 33mm
Panel Cutout182mm x 137mm
C.T. Secondary5A  Rated 
Working ConditionsTemperature:(-25~+70)℃  Humidity:(20~90)%
Storage Condition Temperature:(-40~+70)℃
Protection LevelIP55: when waterproof rubber seal installed between controller and panel fascia. 
Insulating IntensityObject: input/output/power 
Quote standard: IEC688-1992 
Test way: AC1.5kV/1min leakage current: 3mA 
Net WeightLXC620=0.448Kg   LXC610=0.433Kg