all electronic device designed to control engine speed with fast and
precise response transient load changes.
(PER5520E is designed for EFC series.)
Isochronous Operation/Steady Stability---- +/-0.25%
or better Supply----12 or 24 VDC Battery Systems(transient&reverse voltage protected)
Power Consumption----50 ma continuous plus acutator current
Maximum Actuator Current at 25celsius (77celsius F)----10 Amps continuous
Specification
RPM Stability
|
<±0.25%
|
Speed Range
|
1KHz ~ 7.5KHz
|
Speed Drift with Temperature
|
Max ±1%
|
IDLE adjustment
|
160 ± 20Hz ~ 95% of set speed
|
DROOP Regulation
|
Minimum 15Hz ±6Hz/ 1 Amp change
|
Maximum: 400Hz ±75Hz/ 1 Amp change
| |
Speed Trim Range
|
± 200Hz (external 1KΩ)
|
AUX Input Sensitivity
|
148Hz / 1V., ± 10Hz, Impedance 1MΩ
|
START FUEL Regulation
|
160 ± 20Hz ~ 70% of set speed
|
RAMP Regulation Time
|
1.5 ~ 20Sec.
|
Output Current at 10V
|
20mA Max.
|
Operating temperature range
|
-40 °c ~ 85 °c
|
Working Humidity Range
|
Maximum 95%
|
Stocking Temp
|
-55 ~ 90 °C
|
Shocking
|
20-100HZ 500mm/Sec.
|
Voltage
|
12V or 24V DC Battery Systems
|
Grounding Pole
|
Negative pole
|
Power Consumption
|
50mA
|
Actuator Current Range(25°c)-(Inductive Load)
|
Min. 2.5A; Max. 10A continuous
|
Signal
|
0.5 ~ 120 RMS
|
Note: The performance parameters in the frequency when measuring 4000Hz