The AVC125-10B2 regulate the level of excitation supplied to the field of a conventional, brushless, synchronous generator. Regulation is achieved by sensing the generator output voltage, converting it to a dc signal, and comparing the signal to a reference voltage. An error signal is developed and used to control the dc field power in order to maintain a constant generator output. Each regulator includes frequency compensation with selectable slope, inverse-time overexcitation shutdown, buildup circuitry, single- or three-phase voltage sensing, single-or three-phase shunt or permanent magnet generator (PMG) power input, parallel droop compensation, and an accessory input. The accessory input provides compatibility with devices such as var/power factor controllers or excitation limiters.
Features :
Features :
sensing: 220VAC
output: 10A/125V
output: 10A/125V
Frequency:400HZ
Specification | K65-12B | K125-10B |
Output power(with a 240 Vac input) | 12Adc @ 65 Vdc Max cfontainuous; 25 Adc @ 125 Vdc forcing for 10 seconds | 10 Adc @ 125 Vdc max continuous. 20 Adc @ 250 Vdc forcing for 10 Seconds. |
AC input power | 100 to 280 Vac, single-phase 50 to 400 Hz; or 63 to 105 Vac three- Phase, 50 to 400 Hz; 1092 VA max Continuous burden | 180 to 280 Vac, single-phase or Three-Phase, 50 to 400 Hz, 1750 VA Max Continous burden. |
AC sensing voltage | 90 to 140 Vac, 50/60 Hz; single-or- Three Phase. | 90 to 140 Vac, 50/60 Hz; single-or- Three Phase. |
External voltage adjust rheostat | 10K ohm, 2W, potentiometer | 10K ohm, 2W, potentiometer |
Regulation accuracy | ±0.5% Average responding | ±0.5% Average responding |
Voltage drift | ±1% voltage variation for a 40 Deg. C Change. | ±1% voltage variation for a 40 Deg. C Change. |
Response time | <4 ms | <4ms |
Frequency compensation | 1 or 2 V/Hz jumper selectable with Knee Adjustable from 45 Hz to 65 Hz | 1 or 2 V/Hz jumper selectable with Knee Adjustable from 45 Hz to 65 Hz |
EMI suppression | Internal filter | Internal filter |
Voltage Build-Up | Internal provisions for automatic Voltage Build-up from generator Residual voltages As low as six Vac | Internal provisions for automatic Voltage Build-up from generator Residual voltages As low as six Vac |
Droop | 1 A or 5 A, <10 VA,adjustable from 0 To 10% at rated input current, 0.38 Power Factor | 1 A or 5 A, <10 VA,adjustable from 0 To 10% at rated input current, 0.38 Power Factor |
Operating and storage temperature | -40 Deg. C to +70 Deg.C | -40 Deg. C to +70 Deg.C |
Shock: | Withstands up to 20 g in each of Three Mutually perpendicular axes | Withstands up to 20 g in each of three Mutually perpendicular axes |
Vibtation: | Withstands the following Accelerations at The stated Frequency: 0.5g; 18 to 2000Hz | Withstands the following Accelerations at The stated Frequency: 0.5g; 18 to 2000Hz |